Available as both inward and outward opening, as well as one and a half door format and as a pair of doors.
Where high noise attenuation is required, a coupled sash '2 + 1' door can be supplied as an outward opening door only.
Usually supplied as double glazed, with the option of triple glazed.
Insulation panel can be fitted to lower light.
Powder coated aluminium clad version available in any of the RAL colours. Such cladding makes the door virtually maintenance free, certainly comparable to uPVC.
High security ironmongery provided as standard.
WINDOW SIZES (FRENCH DOORS - SINGLE)
These sizes are for the outside frame dimensions.
Width
Height
Minimum
600mm
1800mm
Maximum
1000mm
2500mm
WINDOW SIZES (FRENCH DOORS - DOUBLE)
These sizes are for the structural opening dimensions.
Width
Height
Minimum
1000mm
1800mm
Maximum
2000mm
2500mm
The minimum sizes are as stated, but there is greater room for flexibility on the maximum size depending upon whether triple or double glazing is required, the number of sashes, and the use and positioning of the door. Our free technical service is here to help you, please contact us with the details of your enquiry so that we can respond immediately.
NOISE ATTENUATION
These figures are for a standard door specification.
Cars travelling at an average of 50hm/h within a city environment
29.9dbRW +ctr
Cars travelling at an average of 90hm/h within a city environment
33.6dbRW +ctr
U VALUES
The values are measured in values of w/m2K, and are for the entire frame, and not purely for the glass.
Double Glazed Outward Opening
Standard Glass
2.6
Plus Low E Glass
1.8
Plus Low E Glass & Argon (Basic Specification)
1.6
Plus Low E Glass, Argon
and using Warm Edge
1.5
Plus 2* Low E Glass, Argon
and using Warm Edge
1.4
Double Glazed Inward Opening
Standard Glass
2.7
Plus Low E Glass
1.9
Plus Low E Glass & Argon (Basic Specification)
1.7
Plus Low E Glass, Argon
and using Warm Edge
1.6
Plus 2* Low E Glass, Argon
and using Warm Edge
1.5
THRESHOLD
Supplied as standard in Oak.
DOWNLOADS
To request an AutoCAD file for this door, please click here To download a PDF profile of this door please click here To download a (Aluminium Clad) PDF profile of this door please click here
For information on Cavity Closers, Frame Formers, Trickle Vents,
Restrictors/Stays, Guarantees and Extended Sills, please go
to our Technical page.